材料システム
Online ISSN : 2435-9734
Print ISSN : 0286-6013
円孔を有するCFRP積層板の損傷進展及びひずみ集中に対する積層構成の影響
小林 訓史荻原 慎二武田 展雄
著者情報
ジャーナル フリー

2000 年 19 巻 p. 15-21

詳細
抄録
Quasi-static tension tests were conducted on CFRP laminates with an open hole to clarify the effect of lamination configuration on both the behavior of microscopic damages and strain concentration factor at the edge of the open hole. Laminate configurations are angle-ply[±θ]s(θ=30,45,60゜) and quasi-isotropic[±30/90]s and [±45/90]s. An open hole was introduced at the center of the specimen. A soft X-ray radiography was used to detect the internal microscopic damage progress. Damage progress was observed in[±30]s,[±30/90]s and[±45/90]s laminate. In the failure process of[±45]s and[±60]s laminates, no damage was observed until the specimen final fracture. These laminates failed in a catastrophic manner. Moiré interferometry was applied to measure the microscopic deformation. The observation with a moiré interferometer revealed the whole-field strain distribution on the specimen surface. The effect of laminate configuration on strain concentration factor was clarified experimentally.
著者関連情報
© 2000 金沢工業大学 材料システム研究所
前の記事 次の記事
feedback
Top