1957 年 10 巻 3-4 号 p. 154-160
A complete expression of dynamical characteristics for electromagnetic seismographs with no electric amplifier has been derived by Tazime. In this paper the same expression is deduced in another way, which is more familiar to seismologists. The method is conducive to easy understanding of physical meanings of the expression. Further, the expression is reduced to one of practical convenience. The new expression is written in terms of usual constants for galvanometer, i. e., period, coil resistance, critical damping resistance, and sensitivity.