抄録
This paper describes the effect of mutual leakage reactance in rotor circuit (Canay reactance) on analysis of generator transient and dynamic behavior. The authors derived a detailed equivalent circuit model for 48P-15.75MVA generator, and analyzed sudden short circuit and load rejection phenomena of the generator by simulations using the electromagnetic transients program (ATP-EMTP), and compared the results with the experimental data. In addition to these analyses, the influence of mutual leakage reactance on analysis of power system dynamic stability was investigated.