ACTA HISTOCHEMICA ET CYTOCHEMICA
Online ISSN : 1347-5800
Print ISSN : 0044-5991
ISSN-L : 0044-5991
REGULAR ARTICLE
An Advanced Detection System for In Situ Hybridization Using a Fluorescence Resonance Energy Transfer-based Molecular Beacon Probe
Narantsog ChoijookhuuYasuaki ShibataTakumi IshizukaYan XuTakehiko KojiYoshitaka Hishikawa
Author information
JOURNAL OPEN ACCESS FULL-TEXT HTML

2022 Volume 55 Issue 5 Pages 119-128

Details
Abstract

In situ hybridization (ISH) is a powerful method for detecting specific RNAs at the cellular level. Although conventional ISH using hapten-labeled probes are useful for detecting multiple RNAs, the detection procedures are still complex and required longer time. Therefore, we introduced a new application of fluorescence resonance energy transfer (FRET)-based molecular beacon (MB) probes for ISH. MCF-7 cells and C57BL/6J mouse uterus were used for ISH. MB probes for ERα mRNA and 28S rRNA were labeled with Cy3/BHQ-2 and 6-FAM/DABCYL, and conventional probes were labeled with digoxigenin. Fluorescence measurements revealed that of more-rapid hybridization kinetics compared to conventional probes. In MCF-7 cells, 28S rRNA was detected in nucleolus and cytoplasm of all cells, whereas ERα mRNA was detected in some nucleolus. In the uterus, 28S rRNA was clearly detected using complementary MB probe, but there were no signals in control slides. Moreover, 28S rRNA was detected in all cells, whereas ERα mRNA was detected mainly in the epithelium. Fluorescence intensity of 28S rRNA was decreased significantly in 1 or 2 base-mismatched sequences, that indicates highly specific detection of target RNAs. In conclusion, the FRET-based MB probes are very useful for ISH, providing rapid hybridization, high sensitivity and specificity.

I.  Introduction

In situ hybridization (ISH) is an important molecular histochemical method for detecting the expression of specific genes in tissues and individual cells [22]. In principle, the expression of specific genes is detected based on the base pairing between a specific probe and a target nucleic acid sequence. Since ISH was first introduced in the field of biomedical research, various labels have been employed for probes, including radioisotopes, haptens, and fluorescent dyes. Radioisotope-labeled probes were initially used for ISH [8, 11]. In addition, a variety of next-generation nonradioactive probes have been developed, such as horseradish peroxidase (HRP)-labeled polyuridine as well as various hapten-based probes [22, 29]. The most common haptens currently used are digoxigenin (Dig) and biotin, and deoxynucleotides themselves can be haptenized by thymine-thymine dimer (T-T dimer) method [1921]. Briefly, these nonradioactive probes labeled with haptens are detected by immunohistochemistry. Additionally, a technique utilizing fluorescent-labeled probes known as fluorescent in situ hybridization (FISH) was developed to enable detection of chromosomes and chromosomal abnormalities such as deletions, translocations, and amplifications [2, 31, 33]. Indeed, FISH has proven to be a powerful method for the analysis of specific DNA, but it is not suitable for analysis of RNA because of high background. Although great achievements were done in multiplex detection and signal amplification, the current procedures are still complex, time consuming, and require experienced personnel [14, 15, 17, 18, 28, 31, 34]. Therefore, simpler and more-rapid detection tools for ISH are needed.

To simplify ISH protocols, we introduced a new detection system that uses a molecular beacon (MB) probe based on fluorescence resonance energy transfer (FRET) using paraffin-embedded tissue sections. The MB probes are a hairpin-shaped, single-stranded oligonucleotide sequence consisting of a loop, stem, fluorophore, and quencher [12]. The loop part of the probe is an oligonucleotide sequence that is complementary to the target mRNA, whereas the stem is formed by annealed complementary sequences at each end of the loop. Fluorophore and quencher molecules are labeled at the 5'- and 3'-ends. When the probe hybridizes with the target sequence, the fluorophore separates from the quencher molecule and produces a fluorescent signal based on the FRET principle. When the probe does not hybridize with the target sequence, the energy from the donor fluorophore is transferred to the acceptor quencher, which is in close proximity, thus preventing production of a fluorescent signal [38]. Also, the unique hairpin structure of the MB probe provides highly sensitive detection due to tiny probes and high-affinity binding to target nucleotides [4].

In practice, FRET-based MB probes are used in a variety of applications, including real-time PCR, genetic analyses, pathogen detection, analyses of nucleic acid–protein interactions, as well as various diagnostic clinical assays [1, 10, 24, 36, 37]. All of these methods provide an indication of the presence of target molecules in biological samples; however, in situ localization of target molecules has not been demonstrated yet. Therefore, we introduced a new application of FRET-based MB probes using cultured cells as well as paraffin-embedded tissues, which are the most widely used sample type in basic histochemical research and medical diagnostics due to good preservation of tissue morphology.

In the present study, a FRET-based MB probe was used for the simultaneous localization of ERα mRNA and 28S rRNAs by ISH. The sensitivity and specificity of the MB probe was confirmed using various control experiments, such as dot blot hybridization, competition and neutralization assays, RNase treatment, and mismatched sequences. We optimized the MB probe for ISH using cultured cells as well as paraffin-embedded tissues, and it was useful for rapid and simultaneous detection of different RNAs at the cellular and tissue levels.

II.  Materials and Methods

Chemicals and biochemicals

β-Cyanoethyl phosphoramidites, 3'-DABCYL CPG (#20-5912), 5'-fluorescein phosphoramidite (#10-5901), and cyanine 3 CPG (#20-5913) were obtained from Glen Research (Sterling, VA, USA). Trizma base, bovine serum albumin (BSA), 3-aminopropyl-triethoxysilane, and Brij L23 were from Sigma Chemical Co. (St. Louis, MO, USA). Paraformaldehyde (PFA) was from Merck (Darmstadt, Germany). 3,3'-Diaminobenzidine–4 HCl (DAB) was from Dojindo Chemicals (Kumamoto, Japan). Deionized formamide was purchased from Nacalai Tesque (Kyoto, Japan). All other reagents used in this study were obtained from Fujifilm Wako Pure Chemicals (Osaka, Japan) and were of high analytical grade.

Cell culture

Human breast cancer cells (MCF-7) were grown in Dulbecco’s modified Eagle’s medium with 10% fetal bovine serum and maintained at 37°C in a humidified chamber with 5% CO2 [32]. Cells were attached to the slide glass pretreated with ethanol and UV irradiation, then fixed with 4% PFA/PBS for 15 min.

Animals and tissue preparation

The uterus from 8-week-old C57BL/6J mice weighing 17–19 g were used in this study. Uterine tissue was obtained at proestrus stage, which is reported as highest level of ERα expression [40]. Mice were kept under constant 12-hr dark/12-hr light conditions and fed normal chow and drinking water ad libitum. The experimental protocol was approved by the Animal Ethics Review Committee of the University of Miyazaki (#2012-502-3). After animals were sacrificed, tissues were obtained and fixed in 4% PFA in PBS (pH 7.4) at room temperature for 24 hr and then embedded in paraffin [35].

DNA synthesis and purification

Probe oligomers were synthesized on a 1-μmol scale using an automatic DNA/RNA synthesizer (Nihon Techno Service, Saitama, Japan) and solid-phase phosphoramidite chemistry. After automated synthesis, the oligomers were cleaved from the support and deprotected by treatment with 28% ammonium hydroxide for 17 hr at 55°C. The crude oligomers were purified by denaturing polyacrylamide gel electrophoresis on a 15% gel. After ethanol precipitation, the purified oligomers were desalted using NAP10 columns (GE Healthcare, Buckinghamshire, UK) and identified by electrospray ionization mass spectrometry (ESI-MS) on a Q Exactive quadrupole-orbitrap mass spectrometer (Thermo Scientific, MA, USA).

Fluorescence measurement

Fluorescence was measured using a JASCO FP-8200 fluorescence spectroscopy (Tokyo, Japan), as described previously [16]. The complementary MB probe for 28S rRNA (1 ng/μl) was annealed by heating at 95°C for 3 min and then cooling (1.0°C/min) and storing at 4°C for 3 hr. MB probe and unlabeled homologous oligo-DNA for 28S rRNA (10 ng/μl) were added to the reaction buffer and incubated at 37°C. Reaction buffer contents were similar with hybridization medium of ISH that containing 10 mM Tris-HCl (pH 7.4), 1 mM EDTA, 0.6 M NaCl, 1× Denhardt’s solution, 250 μg/ml yeast tRNA, 125 μg/ml salmon sperm DNA, and 40% deionized formamide. Just after mixing, as well as 3, 6, 12 and 24 hr, fluorescence spectra of the mixture were measured. The excitation wavelength for the probe was 495 nm and the fluorescence emission was monitored at 520 nm. For each sample, at least two spectrum scans were accumulated over a wavelength range of 400 to 700 nm. For mismatch experiments, the complementary MB probe for 28S rRNA was incubated with excess amount of homologous and 1 or 2-base mismatched oligo-DNA, as well as unrelated sequences. After 3 hr of incubation at 37°C, the fluorescence intensity was measured.

Sequences and design of molecular beacon probes

The oligonucleotide probes used for ISH were listed in Table 1. 28S rRNA and ERα mRNA probe sequences were examined previously by Yoshii et al. and Hishikawa et al. [13, 42]. The loop sequence (target mRNA sequence) of MB was selected as a region with 35–65% GC content and a sequence with a predicted melting temperature (Tm) of ~65°C. As described previously, a five-base stem with a GC content of ~60% was attached respectively to the 3' and 5' ends of the loop sequence to prepare a stem-loop hairpin structure with a Tm of ~50°C, which can be determined using the online tool ‘DNA Mfold’ in the experimental condition used in this study (0.6 M NaCl) [41].

Table 1.  Oligo-DNA probe sequences for ISH
Target Probe Sequence and labeling
MB-28S rRNA Complementary FAM 5'-CCTGCtactaccaccaagatctgcacctgcggcgGCAGG-3' DABCYL
Homologous FAM 5'-CCTGCcgccgcaggtgcagatcttggtggtagtaGCAGG-3' DABCYL
MB-ERα mRNA Antisense Cy-3 5'-ATGGCgaggggctccagctcgttcccttggatctggtgcagcaagGCCAT-3' BHQ2
Sense Cy-3 5'-GAGGGatggccttgctgcaccagatccaagggaacgagctggagcCCCTC-3' BHQ2
Dig-28S rRNA Complementary 5'-tgctactaccaccaagatctgcacctgcggcggc-3' Dig
Homologous 5'-gccgccgcaggtgcagatcttggtggtagtagca-3' Dig
Mismatched probes in complementary sequence (28S rRNA)
1-mismatch FAM-5'-CCTGCtactaccaccaagacctgcacctgcggcgGCAGG-3'-DABCYL
2-mismatches FAM-5'-CCTGCtactaccactaagatctgcgcctgcggcgGCACC-3'-DABCYL
Mismatched homologous sequences (28S rRNA)
1-mismatch gccgccgcaggtgcaggtcttggtggtagtagca
2-mismatches gccgccgcaggcgcagatcttagtggtagtagca
Unrelated and unlabeled oligo-DNA ccagtcctctgcgctcccccacgcctcatttgcgacagtcgcgtt

* For MB probe, stem and loop sequences are indicated as capital and small letters, respectively.

Dot blot hybridization

The procedures for dot blot hybridization were described previously [14, 19]. Two-microliter solution of homologous oligo-DNA for 28S rRNA were placed onto nitrocellulose membranes pretreated with 20× SSC (1× SSC = 0.15 M sodium chloride and 0.015 M sodium citrate, pH 7.0) in a series of spots at 1 pg to 10 ng per spot. After baking at 80°C for 2 hr, the membranes were incubated at 37°C for 2 hr with prehybridization medium containing 10 mM Tris-HCl (pH 7.4), 1 mM EDTA, 0.6 M NaCl, 1× Denhardt’s solution, 500 μg/ml yeast tRNA, 250 μg/ml salmon sperm DNA, and 50% deionized formamide. The membranes were then hybridized at 37°C for 3 hr with complementary and homologous MB probes in medium containing 10 mM Tris-HCl (pH 7.4), 1 mM EDTA, 0.6 M NaCl, 1× Denhardt’s solution, 250 μg/ml yeast tRNA, 125 μg/ml salmon sperm DNA, 10% dextran sulfate, and 40% deionized formamide. After successive washing, the membranes were observed using a Fujifilm LAS-3000 luminescent image analyzer (Fujifilm, Tokyo, Japan).

In situ hybridization

ISH followed a previously described standard protocol [6, 19]. Tissue sections were deparaffinized with toluene and rehydrated using a graded ethanol series, followed by treatment with 0.2 N HCl for 20 min and proteinase K digestion at 37°C for 15 min. After post-fixation with 4% PFA in PBS, the sections were immersed in 2 mg/ml glycine in PBS for 30 min and kept in 40% deionized formamide in 4× SSC until used for hybridization. Tissue sections were hybridized with MB probe for 3 hr at 37°C. Control experiments using Dig-labeled oligo-DNA probes were hybridized for overnight. The slides were washed three times with 2× SSC at 37°C and then twice with 2× SSC at room temperature. DAPI was used for nuclear counterstaining. Excess amounts of unlabeled complementary and homologous oligo-DNAs for 28S rRNA (100×) were used for competition and neutralization assays, respectively. Adjacent sections were digested with 100 μg/ml RNase prior to post-fixation for 1 hr at 37°C. In addition, an excess amount of unrelated unlabeled probe was applied together with the 28S rRNA probe. In parallel with MB probe, Dig-labeled 28S rRNA probe was examined in every experiment [42]. For mismatch experiment, mouse uterine tissue was hybridized with complementary MB for 28S rRNA, as well as 1 or 2 base-mismatched probes. The fluorescence intensity was measured in 100 cells in each groups and results were revealed as an average arbitrary fluorescence unit (ImageJ software, 1.53c NIH) [7, 32]. Microphotographs were taken using a laser scanning microscope (Zeiss LSM700), fluorescence microscope (Keyence BZ-X700), and light microscope (Olympus BX53) super resolution microscope (Olympus SpinSR10).

III.  Results

Sensitivity of the MB probe

The principle of FRET-based MB probe was described in Figure 1. When the MB probe hybridizes with the target sequence, the fluorophore and the quencher molecules become distant and produces a fluorescent signal. The sensitivity of the MB probe was evaluated by dot blot hybridization. A total of 10 pg of oligo-DNA could be detected when the complementary MB probe for 28S rRNA was hybridized with unlabeled homologous oligo-DNA fixed on a nitrocellulose membrane (Fig. 2A). The homologous MB probe for 28S rRNA did not hybridized. In parallel with these experiments, 10 pg of oligo-DNA was detected using complementary oligo-DNA for 28S rRNA, but not homologous 28S rRNA probe (Fig. 2B). These findings indicated that the MB probes are highly sensitive probe.

Fig. 1.

Principle of in situ hybridization using the MB probe. The complementary sequence to target molecule is designed in the loop part of the probe. Stem part is formed by annealed complementary sequences and both the 5'- and 3'-ends were labeled with fluorophore and quencher molecules. After probe hybridization, the distance between the fluorophore and quencher molecules increases, enabling emission of fluorescence.

Fig. 2.

Dot blot hybridization. Various amount (1 pg to 10 ng per spot) of homologous oligo-DNA for 28S rRNA were spotted and then membranes were hybridized with complementary and homologous MB probes (A) and Dig-labeled (B) complementary and homologous oligo-DNA for 28S rRNA. 10 pg DNA were detected specifically.

Fluorescence intensity of the MB probe

Fluorescence intensity of MB probe was measured by fluorescence spectroscopy at 0–24 hr after hybridization. After annealing, the complementary MB probe for 28S rRNA was gradually cooled-down to form a stem-loop conformation. Just after mixing with an excess amount of unlabeled homologous oligo-DNA (Fig. 3A), very low fluorescence intensity was observed (black line) (Fig. 3B). After 3 hr of incubation at 37°C to allow for hybridization of the MB probe with the target, a dramatic increase in fluorescence intensity was observed (red line). Interestingly, similar fluorescence intensity was observed at 3, 6, 12, and 24 hr after hybridization. These results indicate that once the MB probe hybridizes with the target sequence, it produces a stable fluorescent signal, regardless of incubation time.

Fig. 3.

Time-dependent fluorescence intensity of the MB probe. The complementary MB probe for 28S rRNA was hybridized with the unlabeled homologous oligo-DNA for 28S rRNA (A) Green color represents fluorophore and red color represents target sequence. The signal was then measured after excitation at 495 nm (B). The black line indicates the fluorescence intensity at the beginning of incubation. The red, blue, green, and orange lines indicate 3, 6, 12, and 24 hr after incubation, respectively.

MB probe for cultured cell line

The usefulness of the MB probe was examined using cultured cells. In MCF-7 cells, the strong fluorescent signal of 28S rRNA was found in all nucleolus as well as throughout the cytoplasm of all cells (arrowheads indicate presence of 28S rRNA) (Fig. 4A). Interestingly, ERα mRNA was found in some nucleolus, but not all (arrows indicate absence in Fig. 4B). Moreover, ERα mRNA was localized mainly in the perinuclear region of the cytoplasm. No fluorescent signals were detected with the homologous MB probe for 28S rRNA (Fig. 4A inset) and sense MB probe for ERα mRNA (Fig. 4B inset). Moreover, the localization of 28S rRNA and ERα mRNA was confirmed by super resolution microscopy, and independent expressions were found in the cell nuclei (Fig. 4D–F). Collectively, these results indicated that the differential subcellular localization of target RNAs can be determined clearly by using ISH with MB probes.

Fig. 4.

In situ detection of ERα mRNA and 28S rRNA in MCF-7 cells. Cells were attached onto a slide glass and reacted with complementary MB probe for 28S rRNA (green) (A) and antisense MB probe for ERα mRNA (red) (B). Both images were merged in (C). Arrowheads indicate presence of 28S rRNA; and arrows indicate absence of ERα mRNA in nucleoli. ERα mRNA was localized mainly in perinuclear region of MCF-7 cells. Another slide was reacted with homologous MB probe for 28S rRNA (inset in a) and sense MB probe for ERα mRNA (inset in B). Magnification ×630. Bar = 10 μm. Cells were analyzed by confocal microscope (A–B) and super resolution microscope (D–F). MB probe for 28S rRNA (D), ERα mRNA (E) and merged with DAPI (F).

Control experiments for the MB probe

Various control experiments were performed to confirm the specificity in the hybridization reaction with MB probe in ISH settings. As shown in Figure 5A, a strong fluorescent signal was observed in the cytoplasm as well as nucleolus in mouse uterus sections hybridized with the complementary MB probe for 28S rRNA, whereas no fluorescent staining was detected in sections hybridized with the homologous MB probe for 28S rRNA (Fig. 5B). Moreover, in competition and neutralization assays, no fluorescent signal was observed when the complementary probes for 28S rRNA were reacted with an excess amount of unlabeled complementary or homologous oligo-DNA for 28S rRNA, respectively (Fig. 5C, D). Further, a similar fluorescent signal to that with the complementary probe was observed in the cytoplasm and nucleolus in sections hybridized with the complementary oligo-DNA for 28S rRNA together with an excess amount of unrelated unlabeled oligo-DNA (Fig. 5E). In addition, no staining was detected when the slides were treated with RNase prior to hybridization with the complementary probes for 28S rRNA (Fig. 5F). Collectively, these results indicate that the MB probe enables specific in situ localization of target RNAs in the tissue sections. Parallel with the MB probe, control experiments were performed using the Dig-labeled oligo-DNA probe for 28S rRNA, and the results were consistent with those obtained with the MB probe (Fig. 5G–L).

Fig. 5.

Control experiments for MB probes. Paraffin-embedded mouse uterus tissue was used for ISH. Uterine sections were hybridized with complementary MB probes for 28S rRNA (green) (A). Adjacent sections were hybridized with homologous (B) and complementary sequences in the presence of excess amounts of unlabeled complementary (C) and unlabeled homologous oligo-DNAs for 28S rRNA (D). Adjacent section was hybridized with the complementary oligo-DNA for 28S rRNA in the presence of an excess amount of unrelated unlabeled oligo-DNA (E). Tissue was treated with RNase prior to hybridization with MB probe for 28S rRNA (F). Uterine sections were hybridized with complementary oligo-DNA probe (G) homologous (H) and complementary sequences in the presence of excess amounts of unlabeled complementary (I) and unlabeled homologous oligo-DNAs (J) for 28S rRNA. Uterine sections were hybridized with the complementary 28S rRNA in the presence of an excess amount of unrelated unlabeled oligo-DNA (K). Tissue was treated with RNase prior to hybridization with complementary oligo-DNA probes for 28S rRNA (L). Magnification ×400. Bar = 20 μm.

Simultaneous detection of ERα mRNA and 28S rRNA using MB probes

In mouse uterus, ERα mRNA and 28S rRNA were detected simultaneously using MB probes. In mouse uterine sections hybridized with complementary MB probe for 28S rRNA, fluorescent signals were observed in all cells (Fig. 6A). Among them, the strongest fluorescent signals were observed in the glandular and luminal epithelium. On the same slide, the antisense MB probe for ERα mRNA was detected in glandular and luminal epithelial cells and some stromal cells (Fig. 6B). Merged image was shown in Figure 6E and arrows indicate co-localization. No signals from homologous MB probe for 28S rRNA (Fig. 6C) and sense MB probe for ERα mRNA (Fig. 6D) were detected in mouse uterine sections.

Fig. 6.

ERα mRNA and 28S rRNA expression in mouse uterine tissue using ISH. Uterine tissue was hybridized with complementary MB probe for 28S rRNA (green) (A) and antisense MB probe for ERα mRNA (red) (B). Both images were merged in (E), and arrows indicate co-localization of ERα mRNA and 28S rRNA expressions. Adjacent uterine section was hybridized with homologous MB probe for 28S rRNA (C) and sense MB probe for ERα mRNA (D). Magnification ×400. Bar = 20 μm.

Discrimination of mismatched transcripts by MB probes

The mismatch discrimination ability of MB probe was tested both in medium and tissue sections. First, mismatch discrimination of MB probe was tested in medium. In this experiment, complementary MB probe for 28S rRNA was mixed with homologous sequence that has 1 or 2 base-mismatches (Table 1) (Fig. 7A). The fluorescent intensity was decreased in 1 or 2 base-mismatched sequences. Minimal fluorescence intensity was found in tube that mixed with unrelated sequence. Then, mismatch discrimination of MB probe was examined in tissue sections. As shown in Figure 7B, a strong fluorescent signal was observed in complementary MB probe for 28S rRNA. However, the fluorescent signal was gradually decreased with 1 or 2 base-mismatched MB probes. No fluorescent signal was detected in sections hybridized with the homologous MB probe for 28S rRNA. When the staining intensity was measured by ImageJ, significant decreases were confirmed between complementary and 1, 2 base-mismatched sequences (Fig. 7C). All these findings demonstrate that the MB probe could discriminate target sequence based on 1 or 2 base-mismatches in both medium and tissue sections.

Fig. 7.

Mismatch discrimination of MB probe. Complementary MB probe for 28S rRNA was hybridized with fully homologous, 1 or 2 base-mismatched sequences, then the fluorescence intensity was measured by fluorescence spectroscopy (A). For control experiment, the unrelated sequence was used. Mouse uterus sections were reacted with complementary MB probe and 1, 2 base-mismatched probes (B). For control experiment, the homologous MB probe was used. Magnification ×400. Bar = 20 μm. Fluorescence signal intensity was measured by ImageJ software and results were revealed as bar-graph (C).

IV.  Discussion

In this study, we introduced a FRET-based MB probe to localize target RNAs in cultured cells and tissue by ISH. Pathological and basic research samples are generally preserved as formalin-fixed paraffin-embedded tissues, and banks of archived tissues preserved in this manner are useful resources for biomedical research [26]. Our results demonstrate that MB probes can be very useful for ISH, providing high sensitivity, specificity, and simpler compared to conventional probes for ISH.

The FRET-based MB probe enabled detection of 28S rRNA with high sensitivity and specificity. In our study, dot blot hybridization could detect as small as 10 pg of oligo-DNA, indicating that the MB probes are sufficiently sensitive for use in ISH, with sensitivity similar to that of Dig-labeled oligo-DNA probes [14]. In order to examine the hybridization kinetics of the MB probes, we measured the fluorescence intensity at 0, 3, 6, 12 and 24 hr using fluorescence spectroscopy. A strong fluorescent signal was observed with 3 hr of incubation, and there was no difference between 3 hr and overnight incubation. Conventional ISH protocols using T-T dimers or Dig-labeled probes require 2 to 3 days to complete, whereas analyses using an MB probe can be completed within 1 day due to the more-rapid hybridization, and an immunodetection system is not necessary for MB probes [21]. Recently, the fast FISH protocol is reported that only 1 hr is required for hybridization, however it is useful for DNA detection, but not for RNA [8, 9]. Therefore, a major advantage of using MB probes is the ability to rapidly detect multiple RNAs due to the comparatively faster hybridization.

Minimal non-specific staining is one of the major advantages of using MB probes, especially when using appropriate fluorophore and quencher molecules [17]. Indeed, the fluorescent dye and quencher molecules should be selected carefully to avoid overlap in the emission spectrum, which could affect fluorescence intensity and background staining [25]. We therefore chose FAM/DABCYL and Cy3/BHQ-2 pairs, which exhibit minimal spectral overlap. Indeed, it is difficult to evaluate background staining for 28S rRNA due to its ubiquitous expression throughout the cell. However, various control experimental results were clearly indicated that MB probe has less background staining in tissue sections. Furthermore, MB probes are also comparable to locked nucleic acid (LNA) probes, which are useful for detecting mRNA and miRNA. The high binding affinity of LNA probes confers both advantages and disadvantages, such as better detection of target sequences but also revealed strong non-specific staining [23]. Also, the major disadvantage of LNA probe is the difficulty to establish control experiments. Therefore, based on the FRET principle, MB probes provide the major advantage of decreased background staining in comparison to LNA, conventional haptens, and fluorescent-labeled probes.

In general, conventional linear probes have two possible states: unbound and bound to the target. However, MB probes have three possible states: free with a stem-loop conformation; free as a random coil; and bound to the target [38]. Based on free energy, the stem-loop conformation is the most stable state and does not produce fluorescence. Although the random coil state can produce fluorescence, unbound probes are washed out after the hybridization step. Therefore, fluorescent signals from the random coil state can be eliminated from tissues. Thus, in tissue sections, fluorescent signals will be produced only by MB probes that have hybridized with target RNAs, which ensures high specificity and minimal background staining [3, 39]. Most importantly, MB probes produce fluorescent signals directly when they bind to the target, without using additional immunohistochemical detection steps, which often cause non-specific staining in conventional ISH. Furthermore, fluorescent labeled probes were often used for FISH, which also uses as direct method. However, FISH is mainly used for DNA detection, but not for RNA. Detection of RNA, such as gene transcripts in cellular and tissue level is important to understand biological processes. Therefore, MB probes are beneficial for specific detection of target RNAs.

In addition, the reason why non-specific binding is reduced and consequently specific staining achieved with the use of MB probes might be that a higher free-energy barrier exists in the hairpin-opening process. A previous report described the potential and free-energy profiles for structured DNA (molecular beacon) and random-coil DNA [5]. Compared to the hybridization of unstructured single-stranded DNA (ssDNA; used in conventional ISH), the hybridization of structured ssDNA (used in this study) must overcome one more energy barrier, which represents the hairpin opening of the MB stem. Overcoming this energy barrier can be achieved with a perfectly matched target. Indeed, MB probes can be used to detect single-nucleotide polymorphisms based on the ability to discriminate single base differences in PCR [27, 30]. In our study, the fluorescence intensity decreased dramatically in 1 or 2 base-mismatch probes in both medium and tissue sections. These findings indicate that MB probes are highly specific for the detection of target RNAs.

In conclusion, ISH using a FRET-based MB probe is a highly sensitive and specific tool that enables simple and rapid detection of specific RNAs in cultured cells and paraffin-embedded tissues.

V.  Conflicts of Interest

We have no conflict of interest to declare.

VI.  Acknowledgments

This study was supported in part by a Grant-in-Aid for Scientific Research from the Japan Society for the Promotion of Science (No. 16K08471, 21K06738 to Y. Hishikawa, No. 19K16477 to N. Choijookhuu). We gratefully acknowledge the Frontier Science Research Center at the University of Miyazaki for allowing us to use their facilities.

VII. References
 
© 2022 The Japan Society of Histochemistry and Cytochemistry

This is an open access article distributed under the Creative Commons Attribution-NonCommercial 4.0 International License (CC-BY-NC), which permits use, distribution and reproduction of the articles in any medium provided that the original work is properly cited and is not used for commercial purposes.
https://creativecommons.org/licenses/by-nc/4.0/
feedback
Top