Journal of Environmental Engineering (Transactions of AIJ)
Online ISSN : 1881-817X
Print ISSN : 1348-0685
ISSN-L : 1348-0685
STUDIES ON PERFORMANCE OF DOMESTIC AIR CLEANERS FOR INDOOR AIR POLLUTANTS AND PREDICTION OF INDDOR CONCENTRATION (PART 1) : The removal effectiveness in environmental tobacco smoke
Atsuo NOZAKIHiromi KIYOSAWASusumu YOSHIZAWA
Author information
JOURNAL FREE ACCESS

2004 Volume 69 Issue 576 Pages 37-42

Details
Abstract
In recent years, air cleaners are often used because of increasing interest in room air quality. However, there is currently no unified method for determining the removal effectiveness of air-cleaners. Here, we report the results of experiments on five type of domestic air cleaner units in a experimental room, using ETS(Environmental Tobacco Smoke). This study was carried out to determine the removal effectiveness of air cleaners on suspended particulate matter evaluated employing an index of equivalent clean air rates(ECAR). The results showed that the removal rates of suspended particulate matter were 59.1〜125.7(m^3/h) for 0.3μm particles, and 115.5〜188.7(m^3/h) for 0.5μm particles respectively with fan-filter units. The rates were much lower for the electro-static collector type unit without fan : 3.9(m^3/h) for 0.3μm particles, and 14.8(m^3/h) for 0.5μm particles respectively
Content from these authors
© 2004 Architectural Institute of Japan
Previous article Next article
feedback
Top