多数室換気に局所相似モデルを適用した場合の通風量予測の精度検証及び戸建住宅の通風量解析への適用
通風時の換気量予測法に関する研究 (第4報)
塚本 健二大場 正昭倉渕 隆後藤 伴延遠藤 智行赤嶺 嘉彦野中 俊宏
著者情報
ジャーナル フリー

2013 年 78 巻 684 号 p. 157-163

詳細
抄録

In the paper, the COMIS-LDSM program was developed that the COMIS code was revised to calculate the discharge coefficients and airflow rates at inflow and outflow openings for arbitrary wind direction. Wind tunnel experiments were performed to validate the prediction accuracy of ventilation flow rates using the COMIS-LDSM and the conventional method. The conventional method overestimated the ventilation flow rates compared to those by COMIS-LDSM, especially when the approaching flow was not normal to the upwind openings. The simulation study was also carried out to calculate ventilation flow rates at a typical detached house in Tokyo in the intermediate season. The cumulative air change rates in the detached house calculated by COMIS-LDSM were predicted by reduction of 4% compared with the conventional method.