戸建て住宅における給湯電力消費量に及ぼす影響要因の分析
―広島地域の全電化住宅を対象とした電力消費量に関する研究―
安藤 元気西名 大作村川 三郎金田一 清香石田 正樹
著者情報
ジャーナル フリー

2013 年 78 巻 692 号 p. 799-807

詳細
抄録

In this paper, the energy consumption of the electrified housing located in Hiroshima area was grasped, and the relationships between the energy consumption by hot water supply system and the housing attributes of residents were examined. To predict the annual and monthly energy consumption, the Quantity Theory Cluster I was applied. Based on the analysis, the factors affecting to the energy consumption were clarified, and the influence of energy consumption was compared among the factors.
As for the predictive equations for energy consumption, the multiple correlation coefficients of annual value and monthly values were explained with 0.852 and 0.740-0.827 respectively. Also, it was clarified that “types of water heater” had major influence on energy consumption throughout a year, and “number of frequency for filling hot water into a bathtub in winter” and “age of the first child of the family” had influence in winter season.