出入口を直交面に配置した防音ユニットの音響特性
那須 恒敏西村 強
著者情報
ジャーナル フリー

2015 年 80 巻 716 号 p. 887-896

詳細
抄録
 Presented here is a concept for manufacturing windows which are capable of ventilating, regulating sunlight and reducing traffic noise inside the homes of the developing countries in tropical climate zones. A previous study discussed a rectangular soundproofing ventilation unit having an inlet and an outlet located on the opposite face, which results in a reduced outlet area. As a result, the ventilation function is reduced.
 To improve this problem, a rectangular soundproofing ventilation unit featuring an inlet and an outlet which is located on the crossed right angle face is proposed in this work. First, the outlet sound pressure is calculated based on the wave equation. Next, to maximize the sound proofing ability, the shape and location of the inlet and the outlet are determined by an investigation of the distribution of higher order mode waves formed inside the soundproofing ventilation unit. Finally, experimental results based on the reverberation chamber method are shown to be in reasonable agreement with our theoretical predictions.
著者関連情報
© 2015 日本建築学会