オフィスの冷房方式の違いが執務者に及ぼす影響に関する被験者実験(その2):夏期空調対比被験者実験における個人属性に着目した生理量・心理量・模擬作業成績の分析結果
臼倉 里津伊香賀 俊治清水 洋佐藤 啓明川上 梨沙伊藤 清
著者情報
ジャーナル フリー

2023 年 88 巻 807 号 p. 387-396

詳細
抄録

The working space environment has a large impact on workers. To improve workplace productivity, it is important to design the office environment. In this paper, we focused on radiant air conditioning, which is attracting increasing attention for use in offices. The purpose of this study was to determine the differences in indoor environment between radiant air conditioning and convective air conditioning and evaluate their effects on workplace productivity by conducting subject experiments.

Radiant air conditioning was found to reduce differences between deep body temperature and terminal skin temperature and to improve creative work performance compared with convection air conditioning.