日本建築学会構造系論文集
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
プレキャスト連層財力壁の水平接合部のすべり強度に関する実験
望月 重小林 高志
著者情報
ジャーナル フリー

1996 年 61 巻 486 号 p. 63-73

詳細
抄録

A multi-story shear wall has often discrete joints without cotter reinforcements at the vertical joints between the wall panels and the surrounding cast-in-place columns. The sliding displacement in joints which display a resistance mechanism different from that of cast-in-place shear wall is expected to occur. In order to investigate the effect of resistant of joints on earthquake resistant performance, a shear failure type experiment was performed on seven multi-story precast concrete walls having a variety of cotter and joint reinforcement ratio at joints. Based on the results of this experiment, the resistance mechanism of a precast concrete multi-story shear wall and a design formula of the slip strength of horizontal joints are proposed.

著者関連情報
© 1996 日本建築学会
前の記事 次の記事
feedback
Top