Journal of Structural and Construction Engineering (Transactions of AIJ)
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
POINT LOAD SOLUTIONS ON LAYERED FLUID-FILLED POROELASTIC SOIL BY THIN LAYERED ELEMENT METHOD AND ITS APPLICATION
Shin-ichiro TAKANOYuzuru YASUIMichio IGUCHI
Author information
JOURNAL FREE ACCESS

1998 Volume 63 Issue 504 Pages 49-56

Details
Abstract

Point load solutions on layered fluid-filled poroelastic soil are derived by thin layered element method using the formulation for transmitting boundary. Ground motions to point load excitations and compliances of circular foundation on fluid-filled poroelastic half-space are compared to verify the presented derivation with those of previous studies. The effect of layered fluid-filled poroelastic soil on impedances of plate foundation, as well as the effect of permeability, are discussed.