日本建築学会構造系論文集
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
乾燥収縮試験法の省力化に関する実験研究
閑田 徹志百瀬 晴基今本 啓一三橋 博三
著者情報
ジャーナル フリー

2008 年 73 巻 628 号 p. 851-857

詳細
抄録
This study aimed at proposing a new drying shrinkage testing method which enables us to save testing labor. For this purpose, Four testing methods were experimentally investigated in comparison with standard testing method specified in Japanese Industrial Standard. As a result of this experiment, a method adopting cylinder specimen embedded mould gage showed highest reproducibility and consistency with the standard method and were revealed an appropriate for this proposal. This proposing method was also demonstrated robustness and high reliability in field experiment and is expected to contribute to rational shrinkage controlling at construction sites.