内圧のオーバーシュートを考慮した外装材設計用風荷重
染川 大輔川口 彰久谷口 徹郎谷池 義人
著者情報
ジャーナル フリー

2008 年 73 巻 628 号 p. 867-873

詳細
抄録
When cladding on a windward wall of a building is broken by a severe storm, the internal pressures may be rapidly increased. The sudden increase of the internal pressure is mentioned as “Aerodynamic Overshoot”, which may cause further damage to other cladding and interior components. This paper investigates the estimation of Overshoot-ratio using a non-dimensional parameter that characterizes the Overshoot phenomenon. This parameter is defined by using the wall opening area, the internal volume of the building, the incident wind speed and the pressure-loss coefficient of an opening. A result of field measurements suggests that the Overshoot-ratio has the values of 1.1 to 1.2 for usual size buildings. As a result, design wind loads for components and cladding on a building should be decided by using the peak internal pressure coefficient of 1.0 in order to prevent the expansion of damage caused by a wall breakages.
著者関連情報
© 2008 日本建築学会
前の記事 次の記事
feedback