日本建築学会構造系論文集
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
柱RC・梁Sとする柱梁接合部の内部パネルのせん断破壊性状
西村 泰志吉田 幹人
著者情報
ジャーナル フリー

2010 年 75 巻 653 号 p. 1393-1400

詳細
抄録

To clarify the shear behavior of the inner panel for RCS system, twelve specimens were tested under monotonic loading. The experimental variables were the thickness of the face bearing plate, the length of loading region and so on. From the test results, it was shown that ultimate shear strength was affected by the thickness of the face bearing plate and the steel flange. An analytical model of the inner panel failing in shear was proposed. This model was composed of two elements, that is, web panel and concrete panel surrounded by the face bearing plate and the steel flange.
Based on this model, analytical formulae were proposed. It was shown that the predictions were in good agreement with the test results.

著者関連情報
© 2010 日本建築学会
前の記事 次の記事
feedback
Top