日本建築学会構造系論文集
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
鉄筋コンクリート造そで壁付き柱のせん断耐力評価
ポリマーセメントモルタルを用いて補強したそで壁付き柱の構造性能 その1
杉山 智昭松崎 育弘
著者情報
ジャーナル フリー

2012 年 77 巻 680 号 p. 1569-1578

詳細
抄録

This paper proposes a seismic retrofitting technique for existing RC columns with cast-in-place RC sidewall using polymer-cement mortar. In the technique, additional shear reinforcement (deformed steel bar: prefabricated reinforcing unit) is adhered to the surface of existing RC columns with RC sidewall by using polymer-cement mortar. Shear-loading tests of the RC columns with RC sidewall were conducted to clarify the structural performance of the columns with sidewall strengthened by polymer-cement mortar. The results suggested that the technique improved the shear capacity of the RC columns with RC sidewall, and clarified the mechanism of shear resistance of the strengthened columns with sidewall. Furthermore, a method of estimating the shear strength of RC columns with RC sidewall strengthened by polymer-cement mortar was proposed by modeling the shear resistance mechanism.

著者関連情報
© 2012 日本建築学会
前の記事 次の記事
feedback
Top