日本建築学会構造系論文集
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
変動軸力および2方向水平力が作用する鉄筋コンクリート立体隅柱梁接合部における降伏破壊および軸崩壊に関する研究
佐野 由宇藤間 淳石川 巧真晉 沂雄北山 和宏
著者情報
ジャーナル フリー

2022 年 87 巻 792 号 p. 217-228

詳細
抄録

Joint hinging failure and succeeding axial failure of a R/C corner column-beam joint were investigated by static tests with three-dimensional beam-column subassemblages under varying axial and bi-lateral loads, where the axial compression stress ratio ranged from 0 to 0.13. Corner joints suffering joint-hinging failure were not able to sustain column axial load at a story drift angle of 3% to 4%, resulted in joint axial failure. This was caused by crushing of joint core concrete, pull-out of a 135-degree hook of joint lateral hoops due to dilation of joint concrete, and buckling of column longitudinal bars in the joint region.

著者関連情報
© 2022, 日本建築学会
前の記事 次の記事
feedback
Top