2024 Volume 89 Issue 822 Pages 862-868
The aim of this study is to clarify characteristics of bearing capacity and settlement of spread foundation after reaching ultimate bearing capacity under horizontal and vertical combined loads. A formula that can equivalate bearing capacity after reaching ultimate bearing capacity was presented. In addition, the validity of the proposed method was examined by experimental results. These results show that settlement of spread foundation after reaching ultimate bearing capacity is little.
Code of Ethics
Ethical standards of the publisher (‘Ethical Standards Concerning the Peer Review for the Presentation of Architectural Transactions and Works’)