日本建築学会構造系論文報告集
Online ISSN : 2433-0000
Print ISSN : 0910-8025
ISSN-L : 0910-8025
柱はり溶接接合部の破壊特性の検討 : 厚板鋼板を用いた柱はり溶接接合部の破壊に関する実験的研究 その1
藤本 盛久橋本 篤秀中込 忠男金 鍾洛松村 弘道
著者情報
ジャーナル フリー

1985 年 349 巻 p. 81-90

詳細
抄録

In many tall steel structures having heavy members and high strenght steel, welding joints have come to be adopted in beam-to-column connection. It is considered that the brittle fracture occurs, when structures are received repetive large strain due to a strong earthquake. It may be that main factors of the brittle fracture are the stress level in the column, a welding method and the stiffness of column web with doubler plates. For such joints having heavy steel members, it remains as important problem how to design beam-to-column connections. This paper describes the influence of the stress level in column on the charactristics of fracture and the structural design method of beam-to-column connections. 10 full scale specimens of sub-assemblage including beam-to-column connections are experimented applying axial force and bending moment. A constant axial force of -0.45, -0.2, +0.1 (axial load/yielding axial load of column) was applied at the column and cyclic vertical force was loaded at the end of beam. The results obtained from the above experiment are as follows, 1) In early stage, the brittle fracture of the specimen applied a tention axial force at a column occure and a crack propagats in the direction of the through-thickness of column flange. 2) The specimens reinforced with doubler plates at column web within connection are more fragile then non reinforced.

著者関連情報
© 1985 一般社団法人日本建築学会