実大建物風洞による通風時の室内表面熱伝達率分布の測定(環境工学)
成田 健一森岡 勲澤地 孝男瀬戸 裕直石川 優美清田 誠良
著者情報
ジャーナル フリー

2005 年 11 巻 22 号 p. 259-262

詳細
抄録
Cross ventilation has the effects to give comfortable feeling by forced convection without any artifical mechanisms. As for the nighttime, it is also useful for cooling down the structure of residence. In this paper, to clarify the heat-removing rate by cross ventilation, the wind tunnel experiments were performed using real scale model house. The distribution of mass transfer coeffient on the floor and indoor wall surfaces were measured by water evaporation method using filter paper. Then heat transfer coefficient was estimated by supposing analogy between mass and heat transfer and its relation to the indoor airflow was also investigated.