日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
構造
中低層住宅用プレキャストCES壁柱の構造性能に関する実験的研究
河本 孝紀倉本 洋尾崎 純二松井 智哉藤本 利昭
著者情報
ジャーナル フリー

2007 年 13 巻 26 号 p. 573-578

詳細
抄録
The experimental study on precast Concrete Encased Steel (CES) columns is outlined and the structural performance of the precast CES columns is discussed in this paper. The precast CES columns are constructed by connecting precast CES elements using bolts and fiber reinforced mortor. Fiver reinforced concrete is used for the precast CES elements. The purpose of this study is to obtain fundamental data on the structural performance and to construct analytical models of the precast CES columns applicable to pushover analysis used in the Calculation of Response and Limit Strength (CRLS).
The results showed that the flexural strength of the precast CES columns is developed by the yielding of their steel and the lateral deformation capacity is about 0.05 rad. in the story drift angle. The shear versus lateral displacement response of the precast CES columns is simulated by the Takeda model.
著者関連情報
© 2007 日本建築学会