日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
構造
高靭性繊維補強セメント複合材料を用いた梁の構造実験
細矢 博福山 洋岸本 剛河野 政典
著者情報
ジャーナル フリー

2010 年 16 巻 32 号 p. 133-138

詳細
抄録
In these years, high-rise apartment buildings with core wall structural system have been constructed. Since span of coupling beams used in the core wall system is too short, large drift angle will be developed. However, RC short span beams do not have excellent ductility under high shear stress condition during earthquake. To resolve this problem, it was decided to use high-performance fiber reinforced cement composite SHCC (Strain-Hardening Cementitious Composites), which exhibits excellent ductility, for short-span beams.
In this study, shear bending tests under antisymmetrical moment condition of SHCC beam specimens were carried out to investigate their structural performances. The accuracy of the calculated flexural strength and shear strength values was also examined.
著者関連情報
© 2010 日本建築学会
前の記事 次の記事