AIJ Journal of Technology and Design
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
Fire Safety
FIRE EXPERIMENT ON DIAGONALLY ARRANGED EXTERNAL LOUVER FOR INTEGRATED FAÇADE SYSTEM
Yutaka MISAWAShigeru HIKONEKenji ABURANOYoshifumi OHMIYAShizuo IWAMOTOMamoru IWATA
Author information
JOURNAL FREE ACCESS

2010 Volume 16 Issue 33 Pages 547-552

Details
Abstract

The building facade plays an important role not only for ornament designs, but also for the safety and environmental impacts of the building. To satisfy these demands, the authors have proposed an integrated facade system using diagonally arranged louvers. When considering the safety, the verification of the behavior of the ejected plume from the building’s openings is important as to prevent the fire from spreading. A full scale fire experiment, in which the louvers were attached to the opening, has been carried out. The ejected plume behavior from the opening was verified through temperature and radiated heat measurement around the opening and the louvers and through study of the shape of the plume.

Content from these authors
© 2010 Architectural Institute of Japan
Previous article Next article
feedback
Top