AIJ Journal of Technology and Design
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
Structures
VERIFICATION OF IDENTIFICATION METHODS FOR LINEAR SYSTEMS UTILIZING SHAKING TABLE TESTS OF FULL-SCALE 4-STORY STEEL BUILDING
Yoshiki IKEDA
Author information
JOURNAL FREE ACCESS

2010 Volume 16 Issue 34 Pages 889-894

Details
Abstract
The already proposed identification methods for linear systems are applied to shaking table tests of a full-scale 4-story steel building at the E-Defense. The structure is modeled as a 4DOF linear shear building in each horizontal direction. Only accelerations recorded at the centers on all floors are utilized for the identification. Natural frequencies, the corresponding damping ratios and modal shapes in the lowest two modes are evaluated by one-input-four-output ARX models. These modal parameters are utilized to identify the mass, damping and stiffness matrices. The results are compared with the structural parameters reported by the E-Defense project team.
Content from these authors
© 2010 Architectural Institute of Japan
Previous article Next article
feedback
Top