日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
防火
可燃性外装の燃え拡がり性状に関するファサード型火災実験
吉岡 英樹西尾 悠平田村 政道吉田 正志野口 貴文兼松 学安藤 達夫小浦 孝次富松 太基尾崎 泰治
著者情報
ジャーナル フリー

2013 年 19 巻 42 号 p. 595-600

詳細
抄録

With regard to fire protection for exterior walls of a building, only ‘fire-resistive performance’ is considered, according to the current building standard law of Japan. In previous studies of authors, new test method for evaluation of fire propagation along combustible cladding, was proposed, using primarily test specimens of facade wall with exterior thermal insulation without vent layer. In this paper, newly made results of facade fire tests with other specimens of combustible facades, such as sandwich panels, photovoltaic sheets, combustible coating materials, and exterior insulation with vent layer etc. are discussed.

著者関連情報
© 2013 日本建築学会
前の記事 次の記事
feedback
Top