陽圧管理空調を用いた病院ろう城区画の遮煙の技術的可能性
川原 大喜土屋 伸一長谷見 雄二
著者情報
ジャーナル フリー

2013 年 19 巻 43 号 p. 971-975

詳細
抄録
In the fire safety design for hospitals, operating suite, ICUs and CCUs are normally protected from fire in adjacent areas by fire separation walls, yet achievement of smoke separation is questionable. This paper discusses feasibility of smoke separation in fire of operating suite, ICU and CCU from other hospital parts utilizing the positive pressure air-conditioning system routinely used for cleaning level control in these areas. The study reveals capability of the normal positive pressure air-conditioning to prevent penetration of smoke from adjacent fires.