日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
構造
カプラー上に帯筋を配さないRC柱のパイロット試験
村山 峻一朗真田 雄介真田 靖士足立 智弘
著者情報
ジャーナル フリー

2014 年 20 巻 46 号 p. 967-970

詳細
抄録
This paper proposes a new hoop arrangement for mechanical splices in RC columns. Pilot tests were conducted using two RC column specimens with/without mechanical couplers where the proposed hoop arrangement was applied. As a result of cyclic loading tests, the proposed hoop arrangement did not significantly affect the column shear performance, namely, damage under allowable shear stress and ultimate shear strength. Feasibility of the proposed method was experimentally verified for practical application.