LATERAL LOADING TESTS OF SHEAR WALLS WITH CONTINUOUS FOOTING FOUNDATION
Study on reinforcing effect of seismic retrofit construction methods for foundation of existing wooden houses part 2
Takafumi NAKAGAWANaohito KAWAI
Author information
JOURNAL FREE ACCESS

2015 Volume 21 Issue 49 Pages 1013-1016

Details
Abstract

In this study, lateral loading tests of shear walls with continuous footing foundation were carried out.
The retrofitting methods used in this study were made by additional concrete casting reinforcing. It was found that the partial retrofitting by the additional concrete casting needed more than 1.82m length and reinforcing of column bottom end joints was also needed when the shear capacity of the added wall was high.

Content from these authors
© 2015 Architectural Institute of Japan