The load carrying capacity of shear walls can be strengthened by increasing the number of nails or screws to the structural panel elements.
However it will be difficult to secure the ductility as the strength increases.
Therefore, in this research, a design method for a true wall type shear wall to ensure high strength and ductility was proposed.
The shear walls were examined for case of using CLT or thick plywood as a structural panel elements.