2018 Volume 24 Issue 57 Pages 733-736
The ecological environmental technique was tried on the 2 story complex building, named “Sustainable Energy Hut” that was built lately at Syowa Station, Antarctica. Air-based solar heating system was applied on the building. The computational fluid dynamics is tried on the indoor thermal environment of the building. Good agreement was found with the field measurement of the indoor temperature and the numerical analysis.
Ethical standards of the publisher (‘Ethical Standards Concerning the Peer Review for the Presentation of Architectural Transactions and Works’)