既存構造物における遮蔽コンクリートの乾燥単位容積質量試験方法の検討
井上 和政徳永 将司北川 高史猪田 幸司山田 俊明中尾 正純
著者情報
ジャーナル フリー

2018 年 24 巻 58 号 p. 901-906

詳細
抄録

Using mold specimens according to JASS 5N T-601, and core specimens taken from the walls specimens, experiments investigating the effect some factors, such as the specimen size, water-binder ratio and cement type on the dry density were carried out. Then a testing method for the measuring dry density of shielding concrete was examined by using the core specimens. As a result, by using the core specimens taken from existing concrete structures, the authors could measure the dry density of shielding concrete based on the method of JASS 5N T-601.