2019 Volume 25 Issue 60 Pages 833-838
The purpose of this experimental study is to clarify dimensions of toilets in a private room in facilities for the elderly. The method is the motion analysis, and the number of participants was ten people.
①When dimensions of toilets were less than 900mm in depth and 1500mm in frontage, it is impossible to do excretion assistance. ②When a wheelchair was placed perpendicular to a toilet, the dimensions that can be assisted without burden was 1300mm in depth and 1800mm in frontage. And when a wheelchair was placed parallel, it was 1400mm in depth and 2000mm in frontage.
Ethical standards of the publisher (‘Ethical Standards Concerning the Peer Review for the Presentation of Architectural Transactions and Works’)