AIJ Journal of Technology and Design
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
Architectural Planning and Design
AN EXPERIMENTAL STUDY ON DIMENSIONS OF TOILETS IN A PRIVATE ROOM IN FACILITIES FOR THE ELDERLY
Kentaro YAMAGUCHI
Author information
JOURNAL FREE ACCESS

2019 Volume 25 Issue 60 Pages 833-838

Details
Abstract

The purpose of this experimental study is to clarify dimensions of toilets in a private room in facilities for the elderly. The method is the motion analysis, and the number of participants was ten people.
①When dimensions of toilets were less than 900mm in depth and 1500mm in frontage, it is impossible to do excretion assistance. ②When a wheelchair was placed perpendicular to a toilet, the dimensions that can be assisted without burden was 1300mm in depth and 1800mm in frontage. And when a wheelchair was placed parallel, it was 1400mm in depth and 2000mm in frontage.

Content from these authors
© 2019, Architectural Institute of Japan
Previous article Next article
feedback
Top