日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
災害
空調室外機および冷却塔の降灰実験
大塚 清敏野畑 有秀諏訪 仁久保 智弘宮村 正光宮城 洋介
著者情報
ジャーナル フリー

2021 年 27 巻 65 号 p. 580-585

詳細
抄録

Experiments on influences of volcano ashfall on building air conditioning equipment are performed. In the experiments, cumulative ashfall depths that can affect the operations of an exterior unit and a cooling tower are mainly concerned because they are placed outdoor and are exposed to ashfall directly at the time of volcano eruption. Through the experiments, cumulative ashfall depths are found to be 10-20mm and 20-30mm for the external unit and the cooling tower respectively, when their operations begin to be recognized deviated from their normal performances.