日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
構造
中央を弾性支持された天井ブレースの弾性座屈耐力の簡易評価法
小林 俊夫
著者情報
ジャーナル フリー

2023 年 29 巻 71 号 p. 103-108

詳細
抄録

Brace is usually installed in aseismic ceiling to keep the aseismic capacity. In the case of high depth ceiling, brace crosses hanging bolt. Experience of several tests show qualitatively that buckling capacity become larger than that of Euler buckling by combining the brace to hanging bolt. Evaluating formula for buckling capacity of brace supported by spring at midpoint is derived and its practical formula is proposed, in which supporting spring ratio ξ and capacity amplifying ratio η are introduced. Buckling capacity of 3 case of lateral loading test results show good agreement with evaluated values by proposed formula.