2023 年 29 巻 73 号 p. 1273-1278
The number of nails, screws or lag-screw-bolt is fixed in some studies about bearing wall using CLT. Additionally, these studies told about a specific wall magnification. Therefore, in this study, we developed a strength adjustable bearing wall using CLT by changing the number of drift pin. We also developed a design method for the bearing wall. We examined the bearing wall and the result showed that our strength adjustable bearing wall attained its target value.