日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
構造
鉄筋コンクリート柱と鉄骨梁で構成されるふさぎ板形式の柱梁接合部の終局せん断耐力
川田 侑子山岡 賢史宮川 和明秋田 知芳稲井 栄一
著者情報
ジャーナル フリー

2024 年 30 巻 76 号 p. 1323-1328

詳細
抄録

Loading tests and FEM analysis were conducted to investigate the ultimate shear strength of beam-column joints of a cover plate type consisting of a reinforced concrete column and steel beams. Based on these results, a design formula for ultimate shear strength was proposed, considering the effects of the width-thickness ratio of the cover plate, the concrete strength of the column-beam joint, and the cross-sectional shapes of the column and beam. Furthermore, the proposed design formula was verified using existing experimental data, and it was shown to have good accuracy.

著者関連情報
© 2024, 日本建築学会