日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
開放式駐車場の性能的火災安全設計ケーススタディ(防火)
南部 晶子中道 明子大松 俊祐北後 明彦野竹 宏彰山口 純一松山 賢富松 太基大宮 喜文萩原 一郎田中 哮義原田 和典
著者情報
ジャーナル フリー

2003 年 9 巻 17 号 p. 191-196

詳細
抄録
A case study was carried out on fire safety design of an open-type car park building. Safety checking was made on evacuation safety, fire fighters' accessibility and structural fire resistance. The design fire was assumed by a successive burning of cars in one row. The fire and smoke were confined within less than quarter of one floor area. By using this benefit, temporal refuge area (TRA) and fire fighting base (FFB) were arranged. Safety of occupants and fire fighters were assessed against fire scenario. The structural frame was constructed by unprotected steel frame, whose stability was assessed by simple plastic theory.