Enzymatic Determination of Pyrophosphate in Urine by Flow Methods
Bartolomé M. SIMONETFélix GRASESJuan G. MARCH
Author information
JOURNAL FREE ACCESS

2003 Volume 19 Issue 7 Pages 1029-1032

Details
Abstract

Two flow methods for the enzymatic determination of pyrophosphate are described that are used to diminish the consumption of reagents. One method is based on the use of an open-close circuit with manual injection using a syringe. The other is a sequential injection method. The analytical features of both methods are: a linear range of 0.4 - 20 mg L-1, an LOD of 0.38 mg L-1, and a CV of 2.0% for the sequential injection method, and a linear range of 0.3 - 15 mg L-1, an LOD of 0.29 mg L-1, and CV of 2.2% for the open-close circuit method. The methods were applied to the determination of pyrophosphate in urine. The pyrophosphate concentration determined in urine samples varied from 1.26 to 6.67 mg L-1.

Content from these authors
© 2003 by The Japan Society for Analytical Chemistry
Previous article Next article
feedback