A Simple and Rapid in situ Preconcentration Method for Trace Ammonia Nitrogen in Environmental Water Samples Using a Solid-Phase Extraction Followed by Spectrophotometric Determination
Minoru OKUMURASachiko HONDAKaoru FUJINAGAYasushi SEIKE
著者情報
ジャーナル フリー

2005 年 21 巻 9 号 p. 1137-1140

詳細
抄録
A simple and rapid in situ preconcentration method for the spectrophotometric determination of trace ammonia nitrogen in environmental water samples has been developed based on solid-phase extraction using a small column packed with octadecyl group-bonded silica gel (Sep-Pak C18 cartridge). A water sample was taken into a graduated syringe for easy and simple operation and prevention of contamination immediately after sample collection. Ammonia in the sample was reacted with hypochlorite and thymol to be converted into indothymol blue; then the formed indothymol blue was collected as an ion pair between indothymol blue and tetrabutylammonium ion on a Sep-Pak C18 cartridge. The indothymol blue on the cartridge was stable for 4 days. The retained indothymol blue was easily eluted with a mixture of methanol and 0.01 mol/l sodium hydroxide solution. The color intensity due to the indothymol blue was spectrophotometrically measured at 725 nm. The proposed method was successfully applied to environmental water samples such as river water.
著者関連情報
© 2005 by The Japan Society for Analytical Chemistry