Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Rapid Communications
A Rapid Field Detection Method for Arsenic in Drinking Water
Anuradha BAGHELBeer SINGHPratibha PANDEYK. SEKHAR
著者情報
ジャーナル フリー

2007 年 23 巻 2 号 p. 135-137

詳細
抄録
In this study, a rapid colorimetric method for arsenic detection was developed. Different reagents containing magnesium turnings in combination with a series of acids were tested for arsine generation. The arsine was then allowed to react with auric chloride on Whatman filter paper No. 3, which in turn changed color. The detection time and detection limit were measured for each acid. Oxalic acid was found to be the most appropriate acid among all the acids used for detection in this study. It took 10 min to detect 10 ppb arsenic concentration and only 1 min to detect concentrations higher than 50 ppb. This method thus reduced the detection time for arsenic and has the potential to develop better field kit.
著者関連情報
© 2007 by The Japan Society for Analytical Chemistry
前の記事 次の記事
feedback
Top