Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Original Papers
Four-way Self-weighted Alternating Normalized Residue Fitting Algorithm with Application for the Analysis of Serotonin in Human Plasma
Ya-Juan LIUHai-Long WUChao KANGHui-Wen GUJin-Fang NIEShan-Shan LIZhi-Yi SURu-Qin YU
著者情報
ジャーナル フリー
電子付録

2012 年 28 巻 11 号 p. 1097-1104

詳細
抄録
A novel algorithm, four-way self-weighted alternating normalized residue fitting (SWANRF), which is an extension of its three-way form, for the decomposition of quadrilinear data with new weight factors, was proposed and applied to the quantitative analysis of serotonin contents in plasma samples. It was observed that the third-order calibration could not only retain a “second-order advantage” and but also obtain other advantages. The introduction of a fourth mode can relieve the serious problem of collinearity, which seems to be one of the “third-order advantages”. The proposed algorithm shows great potential as a promising alternative for the third-order calibration of a four-way data array by contrasting with four-way parallel factor analysis (four-way PARAFAC). Furthermore, both algorithms mentioned above were utilized to analyze the 5-hydroxytryptamine (serotonin) contents in plasma samples by obtaining four-way array (excitation-emission-pH-sample) data, and produced satisfactory results. The serotonin contents in plasma samples obtained by using four-way SWANRF and four-way PARAFAC were 0.324 ± 0.005 and 0.348 ± 0.006 nmol mL−1, respectively.
著者関連情報
© 2012 by The Japan Society for Analytical Chemistry