Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Original Papers
Interference-free Determination of Indole-3-Acetic Acid in Two Real Systems Using Second-order Calibration Method Coupled with Excitation-emission Matrix Fluorescence
Xiu-Fang YANHai-Long WUXiang-Dong QINGYan-Mei SUNRu-Qin YU
Author information
JOURNAL FREE ACCESS

2014 Volume 30 Issue 4 Pages 489-494

Details
Abstract
In this work, a simple and practicable method that combines excitation-emission matrix (EEMs) fluorescence with a second-order calibration method based on parallel factor analysis-alternative least-squares (PARAFAC-ALS) algorithm was developed for the direct interference-free determination of indole-3-acetic acid (IAA) in two real systems, coconut water (CW) and coconut milk (CM). Although the excitation and emission profiles of IAA heavily overlapped with that of unknown interferents in the complex real systems, the actual contents and satisfactory recoveries were still obtained successfully. The contents of IAA in CW and CM were 10.8 ± 0.3 and 4.9 ± 0.2 μg mL−1, respectively, which were consistent with those reported by LC-MS/MS assays in the reference material. The average spike recoveries of IAA in the validation set based on CW and CM were 102.1 ± 3.2 and 98.0 ± 1.9%, respectively. In addition, routine experiments were performed for establishing the validity of the assay to internationally accepted criteria.
  Fullsize Image
Content from these authors
© 2014 by The Japan Society for Analytical Chemistry
Previous article Next article