Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Original Papers
Construction of an Electrode Modified with Gallium(III) for Voltammetric Detection of Ovalbumin
Kazuharu SUGAWARAMakoto OKUSAWAYusaku TAKANOToshihiko KADOYA
Author information
JOURNAL FREE ACCESS

2014 Volume 30 Issue 6 Pages 649-655

Details
Abstract

Electrodes modified with gallium(III) complexes were constructed to detect ovalbumin (OVA). For immobilization of a gallium(III)-nitrilotriacetate (NTA) complex, the electrode was first covered with collagen film. After the amino groups of the film had reacted with isothiocyanobenzyl-NTA, the gallium(III) was then able to combine with the NTA moieties. Another design featured an electrode cast with a gallium(III)-acetylacetonate (AA) complex. The amount of gallium(III) in the NTA complex was equivalent to one-quarter of the gallium(III) that could be utilized from an AA complex. However, the calibration curves of OVA using gallium(III)-NTA and gallium(III)-AA complexes were linear in the ranges of 7.0 × 10−11 – 3.0 × 10−9 M and 5.0 × 10−10 – 8.0 × 10−9 M, respectively. The gallium(III) on the electrode with NTA complex had high flexibility due to the existence of a spacer between the NTA and the collagen film, and, therefore, the reactivity of the gallium(III) to OVA was superior to that of the gallium(III)-AA complex with no spacer.

  Fullsize Image
Content from these authors
© 2014 by The Japan Society for Analytical Chemistry
Previous article Next article