Quasi-Elastic Laser Scattering Method for Monitoring Capillary Wave Frequency at a Water/Nitrobenzene Interface
Satoshi TAKAHASHIAkira HARATATakehiko KITAMORITsuguo SAWADA
著者情報
ジャーナル フリー

1994 年 10 巻 2 号 p. 305-308

詳細
抄録
A quasi-elastic laser scattering (QELS) method was applied to monitoring the capillary wave frequencies at a water/ nitrobenzene interface. A digital spectrum analyzer was adopted to improve the time resolution of the QELS method. As a result, each power spectrum could be obtained in 1s and saved in an additional 1s. The equipment was checked by monitoring capillary wave frequencies at a water/nitrobenzene interface covered with a monolayer of dipalmitoylphosphatidylcholine (DPPC), i.e. changes of interfacial tension caused by the formation of the monolayer at the interface were detected. The equipment was then applied to a chemical oscillation system. It was found that the interface of the chemical oscillation system was covered with a high density membrane during the chemical oscillation.
著者関連情報