Annals of Vascular Diseases
Online ISSN : 1881-6428
Print ISSN : 1881-641X
ISSN-L : 1881-641X
Original Article
Abdominal Aortic Neck Wrap for Refractory Type 1a Endoleak: A Case Series and a Novel Intraoperative Assessment Technique
Ali Kordzadeh Tamer SayedManfred J. RamirezIoannis PrionidisAdam HowardTom Browne
Author information
JOURNAL OPEN ACCESS

2021 Volume 14 Issue 1 Pages 19-22

Details
Abstract

Objective: Refractory type 1a endoleak after endovascular aneurysm repair (EVAR) can pose a significant challenge to surgeons and interventional radiologists. Continuous sac expansion results in aneurysm rupture and mortality. In such circumstances, an external infrarenal aortic wrap could serve as an essential and alternative solution.

Methods: We assessed the application of an infrarenal aortic neck wrap for the treatment of refractory type 1a endoleak in n=6 consecutive patients along with the introduction of a novel assessment technique in order to assure their intraoperative success with no radiation exposure and contrast use.

Results: The median sac expansion was 8.5 mm (interquartile range [IQR], 5–20 mm). The median neck diameter and length of the aortic neck were 23 mm (IQR, 18–25 mm) and 21 mm (IQR, 18–25 mm), respectively. The median length of follow-up post wrap is 24 months (IQR, 14–34 months). There was no associated mortality or morbidity and requirement for any further interventions.

Conclusion: The study demonstrates that aortic wrapping for the treatment of refractory type 1a endoleak for any given neck diameter and length is safe, effective, and long lasting. The suggested novel intraoperative assessment technique contributes to the safety of the procedure by diminishing the need for intraoperative radiation exposure, contrast, and shorter operative time.

Content from these authors
© 2021 The Editorial Committee of Annals of Vascular Diseases. This article is distributed under the terms of the Creative Commons Attribution License, which permits use, distribution, and reproduction in any medium, provided the credit of the original work, a link to the license, and indication of any change are properly given, and the original work is not used for commercial purposes. Remixed or transformed contributions must be distributed under the same license as the original.