Intraoperative Migration of Open Stent Graft Detected by Transesophageal Echocardiography: Report of Two Cases
Kazumasa OrihashiMiwa TashiroNobuo KondoKazuki KiharaMasaki YamamotoSeiichiro WariishiTakashi FukutomiHideaki NishimoriTaijiro Sueda
Author information
JOURNAL FREE ACCESS

2014 Volume 7 Issue 1 Pages 75-78

Details
Abstract
We report two cases of graft migration during open stent grafting, detected by transesophageal echocardiography (TEE). The incidence was 3.7% in our series. The length of landing zone was reduced from 45 mm to 25 mm in case 1 and from 50 mm to 22 mm in case 2 before chest closure. Aneurysmal protrusion on the greater curvature with thin mural thrombus were findings common in both cases. Although additional intervention was not done based on the TEE findings of no endoleak and thrombus formation in the aneurysm, and postoperative course was uneventful, meticulous imaging check-up was needed.