Bioscience, Biotechnology, and Biochemistry
Online ISSN : 1347-6947
Print ISSN : 0916-8451
Food & Nutrition Science Notes
Protocol for Measuring the Endurance Capacity of Mice in an Adjustable-current Swimming Pool
Wataru MIZUNOYAShinichi OYAIZUKengo ISHIHARATohru FUSHIKI
Author information
JOURNAL FREE ACCESS

2002 Volume 66 Issue 5 Pages 1133-1136

Details
Abstract
  We re-examined the methods used in an adjustable-current swimming pool for evaluating the endurance capacity of mice to improve the sensitivity and reproducibility. We found that the BALB/c strain was most suitable to minimize the variation in time taken to swim to the point of fatigue. We found that precise adjustment of the apparatus and the use of three primary swimming trials to select mice before a study made the swimming time more uniform. This procedure was used to establish a more precise evaluation protocol.
Content from these authors

This article cannot obtain the latest cited-by information.

© 2002 by Japan Society for Bioscience, Biotechnology, and Agrochemistry
Previous article Next article