Bioscience, Biotechnology, and Biochemistry
Online ISSN : 1347-6947
Print ISSN : 0916-8451
Biochemistry & Molecular Biology Regular Papers
Quantification of Genetically Modified Soybeans Using a Combination of a Capillary-Type Real-Time PCR System and a Plasmid Reference Standard
Akie TOYOTAHiroshi AKIYAMAMitsunori SUGIMURATakahiro WATANABEHiroyuki KIKUCHIHisayuki KANAMORIAkihiro HINOMuneharu ESAKATamio MAITANI
Author information
JOURNAL FREE ACCESS

2006 Volume 70 Issue 4 Pages 821-827

Details
Abstract

Because the labeling of grains and feed- and foodstuffs is mandatory if the genetically modified organism (GMO) content exceeds a certain level of approved genetically modified varieties in many countries, there is a need for a rapid and useful method of GMO quantification in food samples. In this study, a rapid detection system was developed for Roundup Ready® Soybean (RRS) quantification using a combination of a capillary-type real-time PCR system, a LightCycler® real-time PCR system, and plasmid DNA as the reference standard. In addition, we showed for the first time that the plasmid and genomic DNA should be similar in the established detection system because the PCR efficiencies of using plasmid DNA and using genomic DNA were not significantly different. The conversion factor (Cf) to calculate RRS content (%) was further determined from the average value analyzed in three laboratories. The accuracy and reproducibility of this system for RRS quantification at a level of 5.0% were within a range from 4.46 to 5.07% for RRS content and within a range from 2.0% to 7.0% for the relative standard deviation (RSD) value, respectively. This system rapidly monitored the labeling system and had allowable levels of accuracy and precision.

Content from these authors

This article cannot obtain the latest cited-by information.

© 2006 by Japan Society for Bioscience, Biotechnology, and Agrochemistry
Previous article Next article
feedback
Top