Biological and Pharmaceutical Bulletin
Online ISSN : 1347-5215
Print ISSN : 0918-6158
ISSN-L : 0918-6158
Notes
Establishment of an Enzyme-Linked Immunosorbent Assay for Measurement of Sotalol
Tetsuya SaitaHiroshi FujitoYukitaka NakanoMasato Mori
Author information
JOURNAL FREE ACCESS

2004 Volume 27 Issue 1 Pages 94-96

Details
Abstract

We have established an enzyme-linked immunosorbent assay suitable for routine monitoring of serum levels of sotalol. Anti-sotalol antibody was obtained by immunizing rabbits with sotalol conjugated with bovine serum albumin using the N-succinimidyl ester method. An enzyme marker was similarly prepared by coupling sotalol with β-D-galactosidase. The detection limit of sotalol by the enzyme-linked immunosorbent assay was approximately 32 ng/ml with 50-μl samples. This assay was specific for sotalol because of very slight cross-reactivity with 4-(methanesulfonylamino)benzonitrile (1.6%), but none with D,L-isoproterenol. Using this assay, drug levels were easily measured in the serum of rabbits after oral administration of sotalol at a single dose of 3 mg/kg. The enzyme-linked immunosorbent assay should be a valuable tool in therapeutic drug monitoring and pharmacokinetic studies of sotalol.

Content from these authors
© 2004 The Pharmaceutical Society of Japan
Previous article Next article
feedback