人工心肺離脱直後に原因不明の気道出血を来たした1症例
本多 泰子金澤 雅笹野 淳日野 博文舘田 武志
著者情報
ジャーナル フリー

2005 年 26 巻 2 号 p. 156-158

詳細
抄録
A 77-year-old man was scheduled for aortic valve replacement to treat his aortic stenosis. After induction of anesthesia with fentanyl and propofol, tracheal intubation was facilitated with vecuronium. A pulmonary artery catheter(PAC) was inserted via the right internal jugular vein without difficulty. The tip of the PAC was seen in the left pulmonary artery on a postoperative chest radiograph. The patient was separated from cardiopulmonary bypass(CPB). During protamine infusion, acute pulmonary hemorrhage occurred through the tracheal tube. Fiberoptic bronchoscopy revealed the right upper bronchus to be the source of bleeding. By this time, 500ml of blood had been lost through the endotrachel tube. The bleeding stopped within 30 minutes without any treatment. We administered aprotinin and antithrombin III to normalize blood clotting. No further bronchial bleeding occurred. We could not identify the cause of hemorrhage, although bronchiectasis, tracheal injury by tracheal intubation, PAC-related perforation of the pulmonary artery, perforation of pulmonary vein by ventricular vent catheter, or a metastatic pulmonary tumor from colon cancer were all considered.