循環制御
Print ISSN : 0389-1844
症例
Five Cases of ABO Non-Identical Red Blood Cell Transfusion during Surgery in an Urban Emergency Hospital
Chihiro TakamatsuMasanori KujyoShotaro SakimuraMisa OkamuraHayashi YoshimuraSumio HokaKazuhisa Matsuda
著者情報
ジャーナル フリー

2012 年 33 巻 1 号 p. 36-39

詳細
抄録
We experienced five cases of ABO-compatible, ABO non-identical red blood cell transfusion during emergency surgery in our hospital between April 2010 and September 2011. Although nadir hemoglobin levels were below the safety margin, prompt O-type red blood cell transfusion could save two B-type female patients. However another three patients, whose massive bleeding occurred during neurosurgery, could not be saved postoperatively.
著者関連情報
© 2012 by Japan Society of Circulation Control in Medicine
前の記事
feedback
Top